Sign In | Join Free | My himfr.com
Home > Relay Test Bench >

Relay Test Bench Compliant with IEC 61811 Supports 1-4 Relays DC 0-110V/AC 0-250V Coil Voltage

    Buy cheap Relay Test Bench Compliant with IEC 61811 Supports 1-4 Relays DC 0-110V/AC 0-250V Coil Voltage from wholesalers
     
    Buy cheap Relay Test Bench Compliant with IEC 61811 Supports 1-4 Relays DC 0-110V/AC 0-250V Coil Voltage from wholesalers
    • Buy cheap Relay Test Bench Compliant with IEC 61811 Supports 1-4 Relays DC 0-110V/AC 0-250V Coil Voltage from wholesalers

    Relay Test Bench Compliant with IEC 61811 Supports 1-4 Relays DC 0-110V/AC 0-250V Coil Voltage

    Ask Lasest Price
    Brand Name : HongCe
    Model Number : hcrtb-008
    Certification : Calibration certificate(cost additional)
    Price : Negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 30 set per month
    Delivery Time : 60 days
    • Product Details
    • Company Profile

    Relay Test Bench Compliant with IEC 61811 Supports 1-4 Relays DC 0-110V/AC 0-250V Coil Voltage

    Relay Test Bench Compliant with IEC 61811 Supports 1-4 Relays DC 0-110V/AC 0-250V Coil Voltage


    Product Description

    The HCRTB-008 Relay Test Bench is a high-performance testing equipment integrating advanced PLC control and a user-friendly touchscreen interface. Designed with a robust bench-type structure, it features anti-static coating, a high-quality etched stainless steel panel, and safety-enhancing components such as a sliding acrylic cover and fire-resistant insulating bakelite workbench. The machine automates key testing processes—including life cycle tests, resistance measurements, and fault judgment—with only manual operations required for product clamping and parameter setting, ensuring efficiency and accuracy.

    Product Uses

    Ideal for relay manufacturers, electrical inspection institutions, and relay users, the HCRTB-008 is engineered to test relay performance comprehensively. It supports quality control in production lines, compliance verification in testing labs, and routine maintenance checks for end-users, ensuring relays meet operational standards before deployment.

    Product Highlights

    • Automated Testing: Automatically conducts life cycle tests (for 2 contact groups simultaneously), coil resistance, contact resistance, and insulation resistance measurements, reducing manual intervention and errors.

    • Multi-Parameter Integration: Tests 1-4 relays independently, with support for single/double poles (NO/NC/NO+NC) and customizable load configurations, eliminating the need for multiple devices.

    • Smart Fault Detection: Pre-sets thresholds for contact adhesion or burnout; automatically stops testing and alarms when faults accumulate to the set count, ensuring reliable judgment.

    • Data Traceability: Stores test data (relay model, resistance values, test cycles) and enables USB export for analysis and printing, facilitating quality tracking.

    • Safety Design: Equipped with an acrylic protective cover and insulating workbench to prevent electrical hazards, ensuring operator safety during high-voltage testing.


    International Reference Standards

    • IEC 61811-1:2017 (Relays - Part 1: Life test methods for electrical contacts)

      • Clause 4.2: Specifies the test procedure for contact life cycles, including energization/de-energization time settings (0.1s-99.9s) and cycle count recording (1-999,999 times).

      • Clause 5.3: Requires automatic fault detection for contact adhesion or persistent open circuits, aligning with the HCRTB-008’s smart judgment function.

    • IEC 60255-5:2019 (Measuring relays and protection devices - Part 5: Contact resistance measurement)

      • Clause 3.3: Defines contact resistance test range (1-1000mΩ) and measurement accuracy, matched by the HCRTB-008’s precision testing capability.

    • IEC 61111:2020 (Insulation resistance testing for electrical equipment)

      • Clause 5.1: Specifies insulation resistance test range (1MΩ-1000MΩ) for coil-contact insulation, which the HCRTB-008 fully complies with.


    Technical Parameters

    Serial Number

    Parameter

    Specification

    1

    Power Supply

    AC 220V±10%, 50Hz

    2

    Tested Relay Poles

    Single pole, double pole; normally open (NO), normally closed (NC), or NO+NC simultaneously

    3

    Number of Tested Relays

    1-4 (independent testing)

    4

    Load Configuration

    1 relay with 1 set of NO/NC contacts → 1 load cabinet; 1 relay with 2 sets of NO/NC contacts → 1 load cabinet

    5

    Coil Voltage

    DC 0-110V (manual adjustment); AC 0-250V (manual adjustment)

    6

    Coil Current Output

    Max 1A (DC); Max 1A (AC)

    7

    Digital Voltmeter

    Accuracy ±0.5%, Resolution 0.1V

    8

    On/Off Test Time

    0.1s-99.9s (PLC programmable)

    9

    Test Cycles

    1-999,999 (power-off memory, automatic stop with sound-light alarm when complete)

    10

    Contact Resistance Test

    1-1000mΩ

    11

    Coil Resistance Test

    1-1000Ω

    12

    Insulation Resistance Test

    1MΩ-1000MΩ

    13

    Data Storage

    Long-term storage of parameters and relay models; USB export supported

    14

    Control Mode

    PLC control with intelligent HMI operation

    15

    Wiring

    2 pairs of high-current terminals (for contacts); 1 terminal block (for coil power)

    16

    Dimensions

    600mm (W) × 450mm (D) × 1400mm (H)

    Quality Relay Test Bench Compliant with IEC 61811 Supports 1-4 Relays DC 0-110V/AC 0-250V Coil Voltage for sale